MANTEL CLEARANCES

In addition to meeting noncombustible mate-
rial clearances, you must also meet required
clearances between fireplace openings and
mantel shelf on each side of the fireplace. If
you do not meet the clearances listed below,
you will need a hood.

Determining Minimum Mantel Clearance
If you meet minimum clearance between man-
tel shelf and top of fireplace opening, a hood
is not required (see Figure 6, page 10).

Determining Minimum Mantel Clearance
When using a Hood
If minimum clearances in Figure 6, page 10
are not met, you must have a hood. When
using a hood there are still certain minimum
mantel clearances required. Follow minimum
clearances shown in Figure 7, page 10 when
using hood.

NOTICE: Surface temperatures

of adjacent walls and mantels be-

come hot during operation. Walls

and mantels above the firebox

may become hot to the touch.

If installed properly, these tem-

peratures meet the requirement

of the national product standard.

Follow all minimum clearances

shown in this manual.

NOTICE: If your installation does

not meet the minimum clear-

ances shown, you must do one

of the following:

• operate the logs only with the

flue damper open

• raise the mantel to an accept-

able height

• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level,

you must maintain the minimum distance
of 14" to combustibles (see Figure 8).

B. If combustible materials are less than 14"

to the fireplace, you must install appliance
at least 5" above the combustible flooring
(see Figure 9).

INsTallaTIoN

Continued

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

14"

Min.

Combustible

Material

Noncombustible Material

Hearth

5"

Min.

Combustible

Material

INSTALLING HEATER ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access to

heater control panel. This will in-

sure adequate air flow and guard

against sooting and controls be-

ing damaged. Raise fireplace floor

with noncombustible material.

Make sure material is secure.

CAUTION: Do not pick up

heater assembly by the logs. This

could damage heater. Only han-

dle base assembly by grates.

IMPORTANT: Make sure the heater burner is
level. If heater is not level, heater will not work
properly.
IMPORTANT: Remote receiver module is at-
tached to the valve by a velcro strap. This module
needs to remain where installed. If removed and
wires cross, this can cause the remote to fail.