Wiring diagram, Troubleshooting, Continued – Design Dynamics PFS VF-18P-MHD User Manual

Page 24: Identifying error signals from receiver

Advertising
background image

www.fmiproducts.com

116986-01H

24

WIRING dIaGRaM

SPARK

SPARK

Pilot

4 AA Batteries

ON/OFF

Switch

Thermocurrent

Interrupter Block

SW

SW

TC

TC

Battery

Compartment

MA

GR

MO

SW

P

A

NE

L

Receiver

Antenna

Ignition Cable

Thermocouple

Thermocurrent
Interrupter Block

Combination Control

ON/OFF Switch

(Optional)

OFF

ON

8 Wire Connecting Cable

Thermocurrent Cable #2

or ON/OFF Switch

Soldered Cable

Thermocurrent

Cable #1

Motor

Knob

MAN Knob

TRoUBlesHooTING

Continued

POSSIBLE CAUSE
Battery nearly down. (When
signal appears the first time ap-
proximately 10 ignitions left)

Cable is not connected, ON/OFF
switch is in OFF position

Ignition not successful, possible
air in supply line

REMEDY
Replace battery

Connect cables

Switch to ON. Repeat
procedure

OBSERVED PROBLEM
Long signals (0.8 second
tone, 0.2 second break) dur-
ing ignition

5 second continuous tone

5 short signals (8.2 second
tone, 0.2 second break)

IDENTIFYING ERROR SIGNALS FROM RECEIVER