4. OPERATING GUIDE - DISCHARGING

G. VIEW AND SET CUTOFF

VOLTAGE

a. Press and hold the Voltage Cutoff View

button. The set cutoff voltage is shown on

the voltmeter display.

b. Use a 1/16 inch (2 mm) slot blade

precision type screw driver set the

Voltage Cutoff Adjust to the desired level.

NOTE: Actual cutoff voltages are slightly

lower than the set nominal voltage in order to

give the battery an "accept advantage" and

allowing the operator to observe a marginal

battery and decide its acceptance or

rejection. The actual cutoff value also

depends on how fast the battery voltage is

changing. Of course, the higher the voltage at

acceptance, the better the battery.

4.6 SETTING DISCHARGE CURRENT

The discharge current in amperes is normally set equal to, or 80% of, the battery

nominal 1-hour capacity rating (please refer to the battery manufacturer's

maintenance manual). For example, a SLAB battery with a 30 ampere-hour 1-hour

capacity rating would be tested with the discharge current set to 24 amperes.

Refer to your battery manufacturer’s maintenance manual for the

recommended discharge times.

Before setting the discharge current the CA-1550 must have been connected to the

battery (see section 4.5) and the AC power switch must have been turned on.

H. SET DISCHARGE CURRENT

Slowly turn the multi-turn Ampere Adjust

knob clockwise to the desired discharge

current. The ammeter displays the current as it

is being adjusted.

NOTE: The current is proceeded with a

negative sign indicating that current is being

drawn from the battery.

CA-1550 CHARGER / ANALYZER - OPERATING MANUAL V1.2

Page 21