Accept ezconfig – Dolphin Peripherals 6100 User Manual

Page 80

Advertising
background image

5 - 4

SuffixID

Specifies the symbology identifier sent
after the decoded/received data.

0

0=No symbology identifier is sent.
1=The Code ID is sent.
2=The AIM ID is sent.
3=The SymModifier is sent.

SoundConnect

Enables and disables
• The sound that ScanWedge makes

when starting up, shutting down, or
restarting.

• The audio notification when an IrDA

session is established and closed and
the serial port is opened and closed.

1

0=Disabled
1=Enabled

Audio notifications for errors can’t
be disabled.

MessageConnect

This key applies only to
the IrDA and serial ports.

Enable and disables a notification
message when an IrDA session is
established and closed and the serial port
is opened and closed.

0

0=Disabled
1=Enabled

Accept EZConfig

This key applies only to
the decoder.

Enables and disables ScanWedge’s
compatibility with EZConfig Client when
decoding bar codes.

1

0=Disabled; ScanWedge processes

EZConfig barcodes as it would
any other barcode.

1=Enabled; ScanWedge recognizes

EZConfig barcodes and passes
them on to the EZConfig Client
for further processing.

Settings Section

The Settings section determines how ScanWedge interprets data from the decoder, serial port, and IrDA
interface.

0 = Disable 1 = Enable

Settings Section
Key

Description

Default
Value

Available Values

Advertising