Decode section, Decode section -9 – Dolphin Peripherals 6100 User Manual

Page 85

Advertising
background image

5 - 9

Decode Section

The Decode section specifies decoder settings when using the decoder with ScanWedge.

ScanWedge Entry

Description

Default
Value

Available Values

Enable

Enables and disables the decoder for
ScanWedge.

1

0=Disabled; decoder is not used.
1=Enabled; decoder sends bar

code data as keystrokes to the
active window.

Trigger

Sets the key used by ScanWedge to
initiate a scan/decode. The key is
registered as a system hotkey and
cannot be registered as a hot key by
any other applications.

42

42=OnScan or Scan key

ContScan

Enables and disables continuous
scan.

0

0=Disabled; trigger key must be

released between scans.

1=Enabled; data is continuously

decoded and sent to the
application while the trigger key
is depressed.

PowerSave

Enables and disables power saving
mode.

Note: This key does not appear in the

ScanWedge.exm file for the
Dolphin 6100/6500/7600.

1

1=Enabled; the decoder

automatically initializes and un-
initializes as needed. A slight
delay occurs when the trigger is
activated.

0=Disabled; the decoder initializes

when the utility starts and un-
initializes when the utility
terminates.

ScanTimeout

Specifies the decode time out in 1/
1000th seconds. If a barcode is not
decoded within the specified timeout
an audio and visual notification
indicates that an error occurred.

5000

X=Time in 1/1000th of a second.

ScanMode

Specifies the decode mode.

1

1=Full Omni/Normal
2=ALD (Aggressive Linear

Decode) mode

4=Quick Omni

LinearRange

Specifies the linear search range to
be used while in ALD mode.

3

X=Range from 1 to 6.

1 indicates a tight vertical range
near the aimer.
6 indicates a vertical range of
the entire height of the imager.