MSD-804FD Users Guide (Command Guide)

6

1.2 LAN Port

The MSD-804FD controls peripheral devices externally using LAN. Connect control devices such as
computers and the MSD-804FD with LAN, and then control the MSD and acquire the status using commands.
For command character notations, see “2 ASCII code”. For control using commands, use ports 6000 to 6999,
1100, and 23. Connection will be disconnected if no communication for 30 seconds or longer after connection.
For LAN settings, refer to “8.11 LAN Settings” in the Users Manual.

[Table 1.2] Spec of LAN communication

Physical layer

10BASE-T (IEEE802.3i)/100Base-TX (IEEE802.3u)

Network layer

ARP, IP, ICMP

Transport layer

TCP
Port used for command control: 23, 1100, 6000 to 6999
Port used for WEB browser control (HTTP): 80, 5000 to 5999

Application layer

HTTP, TELNET

[Figure 1.2] LAN connector

1.2.1 The number of TCP-IP connections

The MSD-804FD can connect up to eight connections (eight ports) at a time. If the MSD is controlled from

nine or more computers, they may not be connected to the MSD.

For nine or more connections, use your software to establish and close TCP-IP connections for each sending

and receiving communication commands. By doing so, ports are occupied and released in the MSD side so
that logically eight or more connections (8 ports) can be connected.

Your PC software

MSD-804FD

TCP-IP
connection

→ (Occupied by 1 port → 7

ports free)

Send command
(@xxx)

Send back command (@xxx)

TCP-IP close

→ (Release 1 port → 8 ports

free)

[Figure 1.3] Increasing connections