IDK MSD-804FD User Manual

Page 98

Advertising
background image

MSD-804FD Users Guide (Command Guide)

98

@GEC

Get control command (Control CEC)

Command
format

@GEC, no

Return value
format

@GEC, no, delay, port, memo, error, ch_1, cec_1 (, ch_2, cec_2・・・)

Parameter

no

: Command number

1 to 32

delay

: Delay time

0 to 999999

port : CEC control

524288 = CEC control

memo:

Up to 14 characters of 20 to 7D except 2C (,). “2 ASCII codes”

error

: Processing if no reply from destination device

0 = Stop, 1 = Execute (Continue)

ch_1-8

: Output

1 = OUT1A, 2 = OUT2A, 3 = OUT3A, 4 = OUT4A, 5 = OUT1B, 6 =
OUT2B, 7 = OUT3B, 8 = OUT4B*

* Values can be got only if Cat5e/Cat6 output option is installed.

cec_1-4

: Control command

0 =Not controll, 1 = POWER OFF, 2 = POWER ON

Only output settings to be controlled are sent.

Example

Send
Receive

@GEC,7

@GEC,7,0,524288,DISPLAY1
ON,0,1,2

Get control command 7.

Delay: 0 ms

Memo: DISPLAY1 ON

Error: Stop

Devices connected to OUT1 is ON.

All other outputs are not controlled.

Related info.

8.12.1 Control commands