section 5

5.5 | wiring the speakers and i.Net

OPs

Power cables (16 gauge/2 conductor – Plenum Rated)

Data cables (CAT 5e or equivalent – 4 pair – Plenum Rated) – Straight Pin 568B Method

Speaker Cables (CAT 5e or equivalent – 4 pair – Plenum Rated) – Straight Pin 568B Method

PREPARATION

Check site drawing for wiring installation diagram

Use wiring diagram to determine approximate wiring lengths:

Approximately 15’ between speakers (Cat 5e 4 pair)
Approximately 3000’ total Data length
(AE Router needed at that point to extend distance)

IMPORTANT: Double-check for long home runs and runs between floors, as these

will require much longer lengths of wire. Check wiring schematics for your project.

For more detail about system wiring, see Section 4 – data cables

POWER CABLES

Power cables are plenum-rated, 16-gauge, two conductor cable

One power supply powers 3 i.Net OP's with paging and/or music (6 OP's masking only)

A common ground must exist

Between i.Net OP to i.Net OP
From the MPI located in the Lencore enclosure to the first i.Net
OP Between Floors

WARNING

NOTE: Do NOT activate power until the Power wires are checked for proper polarity and all

the i.Net OPs are wired for power in a power zone. DO NOT SKIP THIS STEP!!! If proper

polarity is NOT maintained, then irreversible damage to the OPs will occur.

DO NOT CONNECT OR DISCONNECT i.NET OPs WITH LIVE WIRE

as injury and shock may occur, and damage may be caused to the equipment.

1

2

3

a

b

A

B

C

a

b

c

18