4 | dry contact- mute & unmute schematic – Lencore Spectra i.Net: Installation and Operations Manual User Manual

Page 46

Advertising
background image

section 6

6.4 |

dry contact- mute & unmute schematic

Schematic 7

Spectra i.Net

®

Sound Masking

Dry Contact – Mute & Unmute Schematic

Top View

+

Connect to dry

contacts to mute and

unmute masking.

Jumper wire from Pin #16 to Pin #20

The i.Lon

®

offers the ability to quickly mute & unmute the sound masking for the entire

system via inputs # 15 & # 19, Input: (input 1- = 15, input 1+ = 19)

Connect a jumper wire from Pin #16 to Pin #20.

Connect the digital input to a set of dry contacts to mute and unmute.

The i.Lon® offers the ability to quickly mute and unmute the sound masking for

the entire system via inputs #15 & # 19.

Connect a jumper wire from Pin #16 to Pin #20.

Connect the digital input to a set of dry contacts to mute and unmute.

-

42

*Closed contact = Mute

Advertising