Selecting the video signal type, Configuring the output, Selecting the video signal type -6 – Extron Electronics MGP 462xi Series User Manual

Page 102: Configuring the output -6, Preliminar y, Html configuration and control, cont’d

Advertising
background image

HTML Configuration and Control, cont’d

MGP Series • HTML Configuration and Control

5-6

PRELIMINAR

Y

To change the name of an input,
1

.

On the Scaler I/O Settings page, select and delete the text in the box under the

desired input number.

2

.

Enter a name of up to 16 characters for the input. The following characters

may be used:

Symbols:

/ : – _ + “ ”

Numerals:

0 through 9

Letters:

Lowercase a through z, uppercase A through Z

Spaces

also can be used.

Selecting the video signal type

Under each input name box is a pull-down menu from which you can select the

video signal type for the input.
Signal type

RGB, YUV-HD, RGBcvS, DVI (DI and HD-SDI

models only), or HD-SDI (HD-SDI models only) are

available on inputs 1 through 4 only. YUVi component

video, S-video, and composite video are available on all

inputs.

The virtual inputs (5 through 19) are displayed on the

screen in groups of three, with one drop-down menu for

each set of three inputs.

For each virtual input group,
• If you select YUVi from the menu, all three

inputs in the group are configured together as

one component video input.

• If you select S-Video,Comp, the first (top) two

inputs are configured as S-video and the

third, as composite.

• If you select Comp,Comp,Comp, each input in

the group is configured as composite video.

Film mode

To place an input in film mode, which enables 3:2 and 2:2 pulldown,

select the Film Mode check box below or to the right of the signal type menu.

If RGB, YUV-HD, DVI, or HD-SDI is selected as the signal type, this check box

is unavailable.

Configuring the output

In the Output Configuration section of the Scaler I/O Settings page, you can select

output parameters from the following pull-down menus:
Resolution

Select the resolution at which the image is displayed on the output

screen.

Refresh Rate

Select the rate in Hz at which the output screen is refreshed.

Sync Format

Select the output signal type required by the display device.

Available formats are RGBHV, RGBS, RGsB, YUV bi-level and YUV tri-level.

Polarity

Select the combination of horizontal and vertical synchronization signal

polarities.

Advertising
This manual is related to the following products: