Preliminar y, Software configuration and control, cont’d – Extron Electronics MGP 462xi Series User Manual
Page 60
Software Configuration and Control, cont’d
MGP Series • Software Configuration and Control
4-8
PRELIMINAR
Y
X6*
= No-password login level
1 through 11 = Entry without password goes to
the level specified if an administrator
password exists.
0 = Entry without password is placed one
level below the lowest password level
(0 through 11).
The response is returned as two digits with a
leading zero if needed.
X6(
= Number of seconds (in tens of seconds) before
timeout on IP connections
X7)
= Number that is inserted into the e-mail message if
the .eml file has an embedded
E
} command
with no parameters.
Use 0 as a placeholder if the optional
X4&
is
used, but
X7)
is not needed.
X50)
= Input 1 through 19
X50@
= Window
0 = All windows (available only for input
selection, Freeze, and window muting)
1 = Window 1
2 = Window 2
3 = Window 3 (MGP 464 models only)
4 = Window 4 (MGP 464 models only)
X50#
= Input video format
1 = RGB
2 = YUV-HD
3 = RGBcvS
4 = YUVi
5 = S-video
6 = Composite
7 = DVI or HD-SDI
X50$
= Test pattern
0 = Off
1 = Color Bars
2 = X-hatch (crosshatch 16x12)
3 = 4 x 4 X-hatch
4 = Grey scale
5 = Ramp
6 = Alt. pixels (alternating pixels)
7 = White field
8 = Crop
9 = Side By Side (4x3 crop)
10 = Quad Split (4x4)
11 = Pip Images (4 x 3 or 16 x 9 PIP column)
12 = 1.78 Aspect (4 x 3/16 x 9 with 1.78 film
aspect ratio)
13 = 1.85 Aspect (4 x 3/16 x 9 with 1.85 film
aspect ratio)
14 = 2.35 Aspect (4 x 3/16 x 9 with 2.35 film
aspect ratio)
N
Patterns #10 and 11 are not available on the
MGP 462xi models.
X50%
= Window text position
0 = None
1 = Bottom left
2 = Bottom center
3 = Bottom right
4 = Top left
5 = Top center
6 = Top right
X3$
= Daylight saving time (used in the northern
hemisphere [USA] and parts of Europe and
Brazil)
0 = off/ignore
1 = on in northern hemisphere
2 = on in Europe
3 = on in Brazil
X3%
= Event number, range = 0 - 99
X3^
= Event buffer
0 = receive
1 = user
2 = NVRAM
X3&
= Event buffer offset (range = 0 to
MaxBufferSize)
X3*
= Event data size
b = bit
B = byte (8 bits)
S = short (16 bits)
L = long (32 bits)
N
This parameter is case sensitive.
X3(
= Event data to write
X4!
= Read password. RS-232/422 connection
responds with the password. The IP
connection responds with 4 asterisks (****)
if a password exists, and with an empty
space if none exists, instead of with an actual
password.
X4$
= Number of bytes to read
X4%
= E-mail event number (1 - 64)
X4^
= E-mail recipient’s address
X4&
= Name of e-mail file to be sent
First line of the file is the subject.
The rest is the body of the e-mail.
X4(
= Default name: a combination of the model-name
and the last 3 character pairs of the unit’s
MAC address (e.g., MGP-464-00-02-3D)
X5!
= Extended security (password) levels: 1-10
The response is returned as two digits with a
leading zero.
X5@
= Connection’s security level
0 = anonymous
1 through 10 = extended security level
11 = user
12 = administrator
X5#
=
(Ethernet only) Number of seconds (stated
in tens of seconds) before timeout on
IP connections (min = 1 (10 seconds),
max = 65000 (650,000 seconds), and
default = 30 (300 seconds). If no data is
received during the timeout period, the
Ethernet connection is closed. Each step
is 10 seconds. When the unit is connected
via RS-232/422, only the global timeout
commands apply; anything else returns
an E13 error code. The response contains
leading zeros.
X5$
= ASCII digit(s) representing the numeric value of
the data element read from the event buffer
(leading zeros are suppressed)
X6^
= Login without password is allowed. If enabled,
the user does not enter a password. After the
user clicks OK, the login level is set based on
the setting in the
X6*
parameter.
0 = Disabled
1 = Enabled