HTML Configuration and Control, cont’d
MGP Series • HTML Configuration and Control
5-20
PRELIMINAR
Y
Horizontal Start Location
— Specify the distance in pixels from the left edge of the
selected input’s total video display area to the left edge of its active area. The
default is 128.
Vertical Start Location —
Specify the distance in lines from the top edge of the
selected input’s total video display area to the top edge of its active area. The
default is 128.
Color
— Adjust the intensity of the colors in the selected window. (At the lowest
adjustment, all colors appear as shades of gray.) The range is 000 to 127; the
default is 064.
Tint
— Change the appearance of the colors in the selected window. The range is
000 to 127; the default is 064.
Contrast
— Increase or decrease the range of image light and dark values in the
selected window. The range is 000 to 127; the default is 064.
Brightness
— Increase or decrease the intensity of video light in the selected
window. The range is 000 to 127; the default is 064.
Detail
— Adjust the sharpness of the image in the selected window. The range is
000 to 127; default is 064.
Pixel Phase
— Adjust the point at which pixels are sampled for the image in the
selected window. The range is 1 to 31; the default is 16.
Total Pixels
— Increase or decrease the width in pixels of the total line of video.
The default is the auto-sensed value. The range is ±512 from the auto-sensed
value.
Active Pixels
— Increase or decrease the width in pixels of the active video area of
the selected input. The default is the auto-sensed value. The range is ±512
from the auto-sensed value.
Active Lines
— Increase or decrease the height in lines of the active video area of
the selected input. The default is the auto-sensed value. The range is ±512
from the auto-sensed value.
Zoom
— Increase or decrease the size of the image in the selected window while
keeping the aspect ratio constant. The range is dependent on the output rate.