SERVICE

7

115

OPTIFLEX 1300 C

www.krohne.com

03/2014 - 4000172306 - HB OPTIFLEX 1300 R07 en

7 Push 4 × [^

^

^

^] to go back to the Operating Mode.

8 Push the [^

^

^

^] button to enter the Configuration Mode (Service).

i

If the device has password protection, The display screen shows the text "CodE2".

9 Give the password for the SERVICE menu. If you do not have the password, speak to the sup-

plier.

10 Record parameters in these menu items: 2.5 M.CAL. SPEED. and 2.7 OFFSET.
11 Push 2 × [^

^

^

^] to go back to the Operating Mode.

12 De-energize the device.
13 Remove the electrical cables.
14 Attach the signal converter cover.

1 Remove the 4 socket head screws at the bottom of the signal converter with a 5 mm Allen

wrench.

2 Remove the signal converter from the process connection. Make sure that you do not damage

the 50 ohm wire.

3 Disconnect the 50 ohm wire connector from the process connection.

Procedure 2A: How to remove the BM 100 signal converter (non-Ex devices)

Figure 7-4: Procedure 2A: How to remove the BM 100 signal converter (non-Ex devices)

WARNING!
De-energize the device and disconnect the electrical cables before you remove the signal
converter.