Row-by-row alarm level setting -23, 23 kpm ii monitor operation, Kpm ii – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual

Page 113

Advertising
background image

TM

Model 3200

M0241-01

Rev. 7/12

6-23

KPM II Monitor Operation

ROW-by-ROW ALARM LEVEL SETTING

(Requires Version V2.05 Or Higher Software - KPM II Stack-

Mode Monitors Only)

This feature allows the audio alarm to be disabled on selected

rows in applications such as planting seed corn.

NOTE: Program system to monitor all planter rows before

performing these steps.

STEP 1 Enter programming mode by pressing and holding

SETUP key. Monitor emits several short beeps,

followed by a long beep. On lower LCD, SETUP icon

turns on and arrow head icon flashes, indicating the

user can select an item to program.

NOTE: Monitor must be in a programmable function (row

spacing, unit, speed, volume or area) to enter setup. Monitor

will not enter setup in seed population or seed spacing.

STEP 2 Press UP or DOWN arrow keys to move flashing

arrow to SEED POPULATION. As arrow icon moves,

the lower LCD will display current setting of each

item selected.

NOTE: Illustrated using rear/front configuration. The

KPM II Stack-Mode console shows LEFT in the left/right

configuration, REAR in the rear/front configuration and

FRONT LEFT/REAR LEFT in the four sections configuration.

The SMM console shows RIGHT in the left/right configuration,

FRONT in the rear/front configuration and FRONT RIGHT/

REAR RIGHT in four sections configuration.

STEP 3 Press the OK key. Row number starts flashing.

STEP 4 Arrow UP or DOWN to desired row.

STEP 5 Press SELECT key. “AVG” starts flashing.

STEP 6 Arrow UP or DOWN to choose one of the following

options.

HIGH - For Early Alarm (70%)

AVG - For Standard Alarm Setting (55%)

LOW - For Failed Alarm Only (25%)

OFF - To Disable Row Alarm

STEP 7 Press and hold the OK key to save alarm setting.

There will be four short beeps, one long beep and the

word “DONE” will appear when the save is completed.

STEP 8 Repeat STEPS 3 through 7 for each row on which

you wish to adjust the alarm setting.

STEP 9 When finished, press SETUP key to exit setup mode.

NOTE: Programming mode may be exited at any time by

pressing SETUP key. Pressing this key will return monitor to

its normal operation. All items changed and saved will come

into effect immediately. Any items changed, but not saved

will revert to the original programmed value.

NOTE: Repeat STEPS 3 through 7 to change seed monitor

back to original settings when special row-by-row alarm

level settings are no longer required.

NOTE: SMM console may not be applicable to
all models.

AREA

OK

CLEAR

ON

OFF

ExIT

ENTER

SETUP

ROW

SPACING

TOTAL

AREA

UNITS

SPEED

VOLUME

SCAN

SEED

SPACING

FIELD

AREA

SPACING

TOTAL

SEED

POP.

FIELD

SELECT

SPEED

SCAN

SETUP

REAR

12

11

10

9

8

7

6

5

4

3

2

1

(1314 15 1617 18)

ROW
SETUP

REAR

SEED

POPULATION

SMM

®

®

SETUP

2

1

FRONT

(12

11

10

9

8

7

6

5

4

3

13 14 15 1617 18)

120
110
100
90
80
70
60
%

120
110
100
90
80
70
60
%

KPM II

NOTE: See “Programming - Row Spacing” for

programming applicable row spacing.

See “KPM I/KPM II Stack-Mode Electronic Seed

Monitors Troubleshooting” in the Troubleshooting

Section.