27 kpm iii monitor operation, Rev. 7/12 – Kinze 3200 Wing-Fold Planter Rev. 7/14 User Manual
Page 117
TM
Model 3200
M0241-01
Rev. 7/12
6-27
KPM III Monitor Operation
STEP 3
Select ‘‘5. Configure Planter Monitor’’ by turning the
knob or using the arrow keys. Press the knob or the
Enter key to display the highlighted item.
NOTE: Press F2 key next to Plant any time Plant option is
available to return to Planter Configuration screen.
NOTE: Planter monitor cannot be reconfigured while planting.
STEP 4
If there are front rows (Interplant) on planter, press
knob or Enter key to highlight “Front Rows” field. A
drop down number pad appears. Turn knob or use
arrow keys to highlight correct value then press tknob
to select number. For numbers containing more than
one digit select one digit at a time. When desired
quantity is displayed above number pad press Enter
key to return to “Kinze Planter Configuration” screen.
If planter has no front rows turn knob or press arrow
keys to advance to “Rear Rows”.
Status
Plant
About
Setup Mode
Configuration:
Effective row spacing: 15.0
Front / Rear
1. General Settings
2. Seed Meter Settings
3. Row Unit Alarm Levels
4. Setup Data Logging
5. Configure Planter Monitor
6. Add New Muxbus Sensors
7. Add Single Interplant Row
8. Select Speed Sensor
9. Sensor Setup
10.Calibrate Speed Sensor
Logdata
SDS = Seed Delivery System
There should be one sensor
for each Row and each Shaft.
Cancel
Kinze Planter Configuration
Planter Type
Sensors Installed
Front Rows
0
OK
Rear Rows
12
Shafts
2
0
Speed
Radar
Vacuum
0
SDS
Hydraulic Level/Temp
0
Downpressure Level
1 2 3
C
4 5 6
7 8 9
.
0
-
STEP 5
Press knob or Enter key to select “Rear Rows” field.
A drop down number pad appears. Turn knob or use
arrow keys to highlight correct value then press knob
to select number. For numbers containing more than
one digit select one digit at a time. When desired
quantity is displayed above number pad, press
Enter key to return to “Kinze Planter Configuration”
screen.
STEP 6
Rotate knob or use arrow keys to advance to “Shafts”
field. Press knob or Enter key to select “Shaft” field.
A drop down menu appears. Turn knob or use arrow
keys to highlight number of “Shafts”. When correct
value is displayed, press knob or Enter key to return
to “Kinze Planter Configuration” screen.
STEP 7
Turn knob or use arrow keys to move to “Speed”
field. Press knob or Enter key and a drop down
menu displays. Select ‘‘Radar’’ or ‘‘Coil Pick-Up’’
(MDS) by turning knob or using arrow keys. When
desired selection is highlighted press knob or Enter
key.
SDS = Seed Delivery System
There should be one sensor
for each Row and each Shaft.
Cancel
Kinze Planter Configuration
Planter Type
Sensors Installed
Front Rows
0
OK
Rear Rows
11
Shafts
2
0
Speed
Radar
Vacuum
0
SDS
Hydraulic Level/Temp
0
Downpressure Level
1 2 3
C
4 5 6
7 8 9
.
0
-
SDS = Seed Delivery System
There should be one sensor
for each Row and each Shaft.
Cancel
Kinze Planter Configuration
Planter Type
Sensors Installed
Front Rows
11
OK
Rear Rows
12
Shafts
2
0
1
2
4
Speed
Radar
Vacuum
0
SDS
Hydraulic Level/Temp
0
Downpressure Level
SDS = Seed Delivery System
There should be one sensor
for each Row and each Shaft.
Cancel
Kinze Planter Configuration
Planter Type
Sensors Installed
Front Rows
11
OK
Rear Rows
12
Shafts
2
2
Speed
Vacuum
0
SDS
Hydraulic Level/Temp
0
Downpressure Level
Radar
Radar
Coil Pick-Up