C13881 | response time when exiting "operational, C13883 | dc active, C13884 | base device synchronisation status – Lenze E84AYCET EtherCAT MCI module User Manual

Page 100: C13885 | clear process data, C13883, Indicates, C13884, C13881, C13885, Is ta

Advertising
background image

13

Parameter reference

13.2

Parameters of the communication module

100

Lenze · E84AYCET communication module (EtherCAT) · Communication Manual · DMS 5.0 EN · 05/2013 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13881

C13883

C13884

C13885

Parameter | Name:

C13881 | Response time when exiting "Operational"

Data type: UNSIGNED_16

Index: 10694

d

= 29C6

h

If the "Operational" state is exited, the response parameterised with

C13880

occurs after the time set here has

elapsed.

A change in monitoring is effective immediately.
Setting range

(min. value | unit | max. value)

Lenze setting

0

ms

65535 0 ms

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13883 | DC active

Data type: UNSIGNED_8

Index: 10692

d

= 29C4

h

The code displays if the DC synchronisation has been activated for the communication module.



Synchronisation with "Distributed Clocks" (DC) ( 37)

Selection list

(read only)

Info

0 DC unused
1 DC for synchronisation

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13884 | Base device synchronisation status

Data type: UNSIGNED_8

Index: 10691

d

= 29C3

h

The code displays whether the inverter is DC-synchronised.



Synchronisation with "Distributed Clocks" (DC) ( 37)

Selection list

(read only)

Info

0 Not synchronised
1 Synchronised

;

Read access … Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT

Parameter | Name:

C13885 | Clear process data

Data type: UNSIGNED_8

Index: 10690

d

= 29C2

h

This code serves to set which process data the slave is to process for maintaining internal communication when the

EtherCAT has exited the "Operational" state.
Selection list

(Lenze setting printed in bold)

Info

0 Use of most recent master PDOs

The data last sent by the master are used.

1 PDOs are set to the value '0'

The process data contents is set to the value '0'.

;

Read access ; Write access … CINH … PLC-STOP … No transfer … PDO_MAP_RX … PDO_MAP_TX … COM … MOT