2 possible causes and remedies, Epl: lost connection to 8400 target [0x01bc3100, Epl: nv memory: no access [0x01bc5531 – Lenze E84AYCEC User Manual
Page 63: Epl: nv memory: read error [0x01bc5532, Epl: nv memory: write error [0x01bc5533, Epl: restart after watchdog reset [0x01bc6010, Possible causes and remedies, 0x01bc3100, 0x01bc5531, 0x01bc5532
EDS84AYCEC EN 3.0 - 09/2012
L
63
E84AYCEC communication manual (Ethernet POWERLINK)
Error messages
Possible causes and remedies
10.2
Possible causes and remedies
This chapter contains all error messages of the communication module in numerical order
of the error number. Possible causes and remedies as well as responses to the error
messages are described in detail.
Short overview of the Ethernet POWERLINK error messages
EPL: Lost connection to 8400 target [0x01bc3100]
EPL: NV Memory: No access [0x01bc5531]
EPL: NV Memory: Read error [0x01bc5532]
EPL: NV Memory: Write error [0x01bc5533]
EPL: Restart after watchdog reset [0x01bc6010]
Response (Lenze setting in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
MCI communication to Inverter Drive 8400 is
interrupted.
• Inverter Drive 8400 is switched off.
• The communication module is not connected
correctly at the MCI slot of the Inverter Drive 8400.
• Switch on Inverter Drive 8400.
• Check screwed connection of the communication
module at the MCI slot of the Inverter Drive 8400.
• Send the communication module and Inverter Drive
8400 together with a description of the fault to Lenze.
Response (Lenze setting in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Access via standard device to the parameter set in the
memory module failed.
Redownload the application (incl. module).
Response (Lenze setting in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Parameter in the memory module could not be read.
Redownload the application (incl. module).
Response (Lenze setting in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Parameter in the memory module could not be written. Redownload the application (incl. module).
Response (Lenze setting in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Communication module is defective.
Send the communication module and a description of
the fault to Lenze.