2 possible causes and remedies, Epl: lost connection to 8400 target [0x01bc3100, Epl: nv memory: no access [0x01bc5531 – Lenze E84AYCEC User Manual

Page 63: Epl: nv memory: read error [0x01bc5532, Epl: nv memory: write error [0x01bc5533, Epl: restart after watchdog reset [0x01bc6010, Possible causes and remedies, 0x01bc3100, 0x01bc5531, 0x01bc5532

Advertising
background image

EDS84AYCEC EN 3.0 - 09/2012

L

63

E84AYCEC communication manual (Ethernet POWERLINK)

Error messages

Possible causes and remedies

10.2

Possible causes and remedies

This chapter contains all error messages of the communication module in numerical order

of the error number. Possible causes and remedies as well as responses to the error

messages are described in detail.

Short overview of the Ethernet POWERLINK error messages

( 62)

EPL: Lost connection to 8400 target [0x01bc3100]

EPL: NV Memory: No access [0x01bc5531]

EPL: NV Memory: Read error [0x01bc5532]

EPL: NV Memory: Write error [0x01bc5533]

EPL: Restart after watchdog reset [0x01bc6010]

Response (Lenze setting in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

MCI communication to Inverter Drive 8400 is

interrupted.

• Inverter Drive 8400 is switched off.

• The communication module is not connected

correctly at the MCI slot of the Inverter Drive 8400.

• Switch on Inverter Drive 8400.

• Check screwed connection of the communication

module at the MCI slot of the Inverter Drive 8400.

• Send the communication module and Inverter Drive

8400 together with a description of the fault to Lenze.

Response (Lenze setting in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Access via standard device to the parameter set in the

memory module failed.

Redownload the application (incl. module).

Response (Lenze setting in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Parameter in the memory module could not be read.

Redownload the application (incl. module).

Response (Lenze setting in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Parameter in the memory module could not be written. Redownload the application (incl. module).

Response (Lenze setting in bold)

Setting: not possible

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Communication module is defective.

Send the communication module and a description of

the fault to Lenze.

Advertising