C13040 | 0x1f82 feature flags, E84aycec communication manual (ethernet powerlink) – Lenze E84AYCEC User Manual

Page 70

Advertising
background image

E84AYCEC communication manual (Ethernet POWERLINK)

Parameter reference

Parameters of the communication module

70

L

EDS84AYCEC EN 3.0 - 09/2012

C13040

The describing bit field has the following structure:

Parameter | Name:

C13040 | 0x1F82 Feature Flags

Data type: UNSIGNED_32

Index: 11535

d

= 2D0F

h

The code displays the Ethernet POWERLINK features implemented by the EPL node.

Lenze standard value: 0x00000207
Value is bit-coded:

Bit 0 ... 31 see below

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Bit

Value

Description

0 (LSB)

0

Asynchronous access

1

Isochronous access

1

0

No SDO by UDP/IP

1

SDO by UDP/IP

2

0

No SDO by EPL "ASnd"

1

SDO by EPL "ASnd"

3

0

No SDO integrated in PDO

1

SDO integrated in PDO

4

0

No "NMT Info Services"

1

"NMT Info Services" supported

5

0

No extended "NMT State Commands"

1

Extended "NMT State Commands" supported

6

0

No dynamic PDO mapping

1

Dynamic PDO mapping supported

7

-

Reserved / No function

8

0

No configuration manager function

1

Configuration manager function

9

0

Only isochronous cyclic access permitted.

1

Isochronous multiplexed access possible.

10

0

No address assignment via software

1

Address assignment via software

11

-

Reserved / No function

12

0

No "Ethernet POWERLINK to standard Ethernet" router function.

1

The device can be used as an "Ethernet POWERLINK to standard Ethernet" router (router

type 1).

13

0

No "Ethernet POWERLINK to fieldbus" router function.

1

The device can be used as an "Ethernet POWERLINK to fieldbus" router (router type 1).

14 ... 31

(MSB)

-

Reserved / No function

Advertising