The describing bit field has the following structure:
Parameter | Name:
C13040 | 0x1F82 Feature Flags
Data type: UNSIGNED_32
Index: 11535
d
= 2D0F
h
The code displays the Ethernet POWERLINK features implemented by the EPL node.
Lenze standard value: 0x00000207
Value is bit-coded:
Bit 0 ... 31 see below
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Bit
Value
Description
0 (LSB)
0
Asynchronous access
1
Isochronous access
1
0
No SDO by UDP/IP
1
SDO by UDP/IP
2
0
No SDO by EPL "ASnd"
1
SDO by EPL "ASnd"
3
0
No SDO integrated in PDO
1
SDO integrated in PDO
4
0
No "NMT Info Services"
1
"NMT Info Services" supported
5
0
No extended "NMT State Commands"
1
Extended "NMT State Commands" supported
6
0
No dynamic PDO mapping
1
Dynamic PDO mapping supported
7
-
Reserved / No function
8
0
No configuration manager function
1
Configuration manager function
9
0
Only isochronous cyclic access permitted.
1
Isochronous multiplexed access possible.
10
0
No address assignment via software
1
Address assignment via software
11
-
Reserved / No function
12
0
No "Ethernet POWERLINK to standard Ethernet" router function.
1
The device can be used as an "Ethernet POWERLINK to standard Ethernet" router (router
type 1).
13
0
No "Ethernet POWERLINK to fieldbus" router function.
1
The device can be used as an "Ethernet POWERLINK to fieldbus" router (router type 1).
14 ... 31
(MSB)
-