In order to be able to install your range or cooktop as soon as it is delivered, you must ensure that in your
kitchen, the gas and electrical supplies are ready for it.
1.1. Ventilation
The use of a gas cooking appliance results in the production of heat and moisture in the room in which it
is installed. It is essential that the kitchen where the "La Cornue" stove will be installed has excellent ven-
tilation
to the outside, for vapor and combustion gases, and a fresh air inlet.
Do not use air recycling systems.
Ventilation exhaust devices can be vapor aspirators or hoods.
1.2. Clearances to combustible construction
The minimum horizontal distance from
sides of appliance to the adjacent vertical
combustible walls extending 18” (457
mm) above the top panel is 12” (305
mm).
The maximum depth of overhead cabinets
is 13” (330 mm).
The minimum horizontal distances
between overhead cabinets is not less then
the nominal width of the appliance (A).
To eliminate the risk of burns or fire
by reaching over heated surface units,
cabinet storage space located above
the surface units should be avoided.
Any element, either an extraction hood or
cabinet, situated directly above the range
must be made of non-combustible material
and placed at no less than 30” (760 mm)
above range.
The recommanded height is 36” (914
mm) above range.
May be installed with zero clearance between adjacent combustible construction below the cooking surface and the back
and sides of the appliance.
To be used in conjonction with a suitable ventilation hood.