Electrical connection

I

NSTALLATION

- mobile homes,
- recreational vehicles or
- in an area where local codes prohibit grounding through the neutral.

The power of the electric elements for each appliance see page 11 and pages 12 - 34.
The overall wattage of your appliance is also indicated on the nameplate label and on the warranty
certificate (See item 1 page 41 for the location of the nameplate label).

Wiring must conform to National Electric Codes.
If the electric service provided does not meet the above specifications, have a licensed electrician install an
approved outlet.

Because range terminals are not accessible after range is in position, flexible service conduit or cord must
be used at least 4 ft (1.2 m) length. The range can then be easily disconnected for servicing.

The "La Cornue" appliance is supplied with a connection terminal block accessible by unscrewing the
stainless steel protection plate on the backside.

1. Remove the screws and the protection plate on the backside of the ranges.
For the cooktops remove the cover of the main terminal box.

2. Now the terminal block is accessible

3. The appliance is shipped with a strain relief device to secure power cord. Insert the power cord through
the strain relief and tighten it.

Ranges

Terminal

block

Cooktops

Ranges

Cooktops