Us a & c – La Cornue Château 75 User Manual

Page 51

Advertising
background image

Page

49

LA CORNUE

Installation Guide Centenaire

08NOTINSTAL100/USA-6

US

A & C

AN

AD

A

Save the orifices removed from the appliance for future use.

If the range is to be used above 3000ft the burner orifices must be changed. This conversion must be
performed by a qualified gas installer.
Read the instructions before converting this appliance.
Failure to convert the appliance correctly could invalidate any warranty or liability claims and lead to
prosecution.

When servicing or replacing gas-carrying components disconnect from gas before commencing operation.
Use the correct orifices for high altitude given by La Cornue service only for your appliance.
When you have completed the changes, check the appliance is gas sound.
CAUTION: DO NOT USE A FLAME TO CHECK FOR GAS LEAKS.

Do not use re-conditioned or unauthorized gas controls.

Save the orifices removed from the appliance for future use.

Check operation of all the burners.

After conversion the installation must comply with the relevant regulations and also the local electricity
supply company requirements.

Remove the brisk heat grill (A), the cap of the burner (B), then the pan (C). The regulator is now accessible.
The regulator has a bayonet mounted top cap. Using a small coin press in and turn the cap to remove it.
Turn the cap over so that the letters “LP” (for propane gas) or “NAT” (for natural gas) are visible on base
of the hollow in the cap. Replace the cap making sure that the bayonet pins are securely located

M

AINTENANCE

Gas Pressure Regulator

WARNING

The conversion kit shal l be instal led by a qualified service
agency in accordance with the manufacturer's instructions and
all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not follo-
wed exactly, a fire, explosion or production of carbon monoxi-
de may result causing property damage, personal injury or loss
of life. The qualified service agency is responsible for the pro-
per installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is chec-
ked as specified in the manufacturer's instructions supplied
with the kit.

4. G

AS

P

RESSURE

R

EGULATOR

3. C

ONVERTING FOR

H

IGH

A

LTITUDE

Advertising
This manual is related to the following products: