Gas connection
4. Insert the strain relief device into the hole and push it to the left. Tight up the power cord and strain
relief device with the screw.
5. Install the power cord: attach the wires to the termi-
nal block as follows:
- neutral (white wire) to N,
- the L1 and L2 (red and black wire) to P1 and P2,
- the ground to T (yellow / green).
NOTE: Make sure the wires are completely inserted
into the terminals and secure connections are made.
6. Re-install the protection plate for the range or the cover for the cooktop.
7. Make sure that everything is properly secured.
R
EMINDER
: connections to main power supply preferably suppose to be hardwired into the wal l Junction Box
compare using the Plugs and Out let.
Fix the cable wel l below the hot air out lets, at the rear of the oven, never in front of them.
The instal lation of your La Cornue appliance must conform with local codes or, in the absence of local
codes, in the USA with the “National Fuel Gas Code”, ANSI Z223.1, latest edition, and, in Canada,
with CAN/CGA - B149.1, and CAN CGA - B149.2, “Instal lation Code for Gas Burning Appliances”.
In The Commonwealth Of Massachusetts
This product must be instal led by a licensed plumber or gas fitter when instal led within the
Commonwealth of Massachusetts.
A “T” hand le type manual gas valve must be instal led in the gas supply line to this appliance.
All La Cornue ranges and cooktops are fully assembled and equipped for use with the type of gas shown
on the rating plate of the appliance.
If no special instructions were mentioned upon ordering, the stove is fitted with orifices for natural gas.
Prior to instal lation, ensure that the local distribution conditions (nature of the gas and gas
pressure) and the adjustment of the appliance are compatible.
The range is designed to operate at a manifold pressure of 5’’ of Water Column (1,24 kPa = 12,4 mbar) on
natural gas, or a manifold pressure of 11’’ of Water Column (2,74 kPa = 27,4 mbar) on LP gas (Propane).
3. G
AS CONNECTION