3 status of the inputs, outputs and leds – Pilz PNOZ mm0p 24VDC User Manual

Page 60

Advertising
background image

Fieldbus modules

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

60

Byte

Content

Example/explanation

256

High Byte diagnostic word.
Element ID=1

See diagnostic word for comment
Element ID = 1,
e.g. diagnostic word of E-STOP:
High Byte:

...

...

355

High Byte diagnostic word.
Element ID=100

0

0

0

0

0

0

0

1

Message: Wiring error, clock error

356 ...

383

Reserved

Status of the inputs, outputs and LEDs
These bytes contain the state of the inputs/outputs plus the LED status

Byte

Content

Example/Comment

384

I0 ... I7 base unit,
IM0 ... I7 base unit Mini

For example: The safety system consists of one base unit PNOZ

m1p and one expansion module PNOZ mi1p
Assignment of Bytes on the base units PNOZmulti

385

I8 ... I15 base unit,
I8 ... I15 base unit Mini

386

I16 ... I19 base unit
IM16 ... IM19 base unit Mini

387

0

388

0

389

I0 ... I7 1st expansion module,

right

Byte 384: PNOZ m1p

390

I0 ... I7 2nd expansion module,

right

I7

I6

I5

I4

I3

I2

I1

I0

391

I0 ... I7 3rd expansion module,

right

Byte 385: PNOZ m1p

392

I0 ... I7 4th expansion module,

right

I15

I14

I13

I12

I11

I10

I9

I8

393

I0 ... I7 5th expansion module,

right

Byte 386: PNOZ m1p

394

I0 ... I7 6th expansion module,

right

0

0

0

0

I19

I18

I17

I16

395

I0 ... I7 7th expansion module,

right

Byte 387: