Operating Manual PNOZmulti communication interfaces
1001154-EN-13

61

Byte

Content

Example/Comment

396

I0 ... I7 8th expansion module

right

0

0

0

0

0

0

0

0

Byte 388:
0

0

0

0

0

0

0

0

Byte 389: PNOZ mi1p
I7

I6

I5

I4

I3

I2

I1

I0

If an input has a high signal, the corresponding bit will be "1"; if

an input has a low signal, the bit will be "0".
INFORMATION:
On the base units PNOZmulti Mini, the status of the configurable

inputs/outputs is only displayed if they are configured as inputs in

the PNOZmulti Configurator.

Assignment of Bytes on the base units PNOZmulti Mini:
Byte 384: PNOZ mmxp
I7

I6

I5

I4

IM3

IM2

IM1

IM0

Byte 385: PNOZ mmxp
I15

I14

I13

I12

I11

I10

I9

I8

Byte 386: PNOZ mmxp
0

0

0

0

IM
19

IM
18

IM
17

IM
16

397 ...

399

Reserved

400

LED I0 ... I7 base unit

For example: The safety system consists of one base unit PNOZ

m1p and one expansion module PNOZ mi1p

401

LED I8 ... I15 base unit

402

LED I16 ... I19 base unit

403

0

Byte 400: PNOZ m1p

404

0

I7

I6

I5

I4

I3

I2

I1

I0

405

LED I0 ... I7
1st expansion module, right

Byte 401: PNOZ m1p
I15

I14

I13

I12

I11

I10

I9

I8

406

LED I0 ... I7
2nd expansion module, right

Byte 402: PNOZ m1p
0

0

0

0

I19

I18

I17

I16

407

LED I0 ... I7
3rd expansion module, right

Byte 403:
0

0

0

0

0

0

0

0

408

LED I0 ... I7
4th expansion module, right

Byte 404:
0

0

0

0

0

0

0

0

409

LED I0 ... I7
5th expansion module, right

Byte 405: PNOZ mi1p
I7

I6

I5

I4

I3

I2

I1

I0

Advertising