7commissioning, 2 commissioning the servo amplifier – Pilz PMCtendo DD5.03/000/0/0/0/110-230VAC User Manual

Page 165

Advertising
background image

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]

7-9

7.2

Commissioning the servo amplifier

7

Commissioning

4. Enable axes

Switch on the mains voltage: Close the S3 switch “Mains on”

Close the S2 switch “HW-Enable”.

Press the

START

button in PScope.

An automatic software enable will be set. In PDrive, the

Enable axis

field

changes from

DISABLE

to

ENABLE

. The motor starts a reverse mode.

5. Perform tuning

Press

Tuning

in PScope and adjust the tuning parameters.

Ensure that the freely rotating motor is not yet connected to the work
machine.

Advertising