The following guidelines are intended to help you carry out the electrical
installation in a sensible order, without forgetting anything important.

Choice of cable

Select cables in accordance with EN 60204

Earthing, shielding

Make sure that shielding and earthing are EMC-compliant

Earth the mounting plate, the motor housing and the control system's
ground terminal. Information on the connection technology can be
found under “Block diagram”.

Wiring

Lay the power and control cables separately

Incorporate the relay output for operational readiness (BTB) into the
plant's safety circuit

Connect the servo amplifier's digital inputs and outputs

Connect the AGND earth (even if a fieldbus is used)

If necessary, connect the analogue setpoint value

Connect the encoder (feedback)

Connect the expansion card

Connect the motor cables

Connect the shielding on both ends; use a motor choke if the cable
runs are over 25 m

Connect the motor holding brake, connect the shielding on both ends

If necessary, connect the external brake resistor (with fuse protection)

Connect the 24 VDC supply voltage (for maximum permitted voltage
values see chapter entitled “Technical Details”)

Connect the mains voltage (for maximum permitted voltage values
see chapter entitled “Technical Details”); for information on FI residual
current devices see section entitled “Residual current devices”)

Connect the PC (see section entitled “Communications interfaces”)

Check

Check the wiring against the wiring diagrams