7 config: mask – Comtech EF Data CDM-750 User Manual

Page 112

Advertising
background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Front Panel Operation

MN-CDM750

5–34

5.2.2.7 CONFIG: Mask

Masks: RxAGC EsNo Reference DeCompInv
LNB

 
Use the W X arrow keys to select RxAGCEsNoReferenceDeCompInv, or LNB, and then press 
ENTER
 
For the RxAGC, EsNo, and LNB submenu selections, three masking options are available. Using the 
RxAGC submenu as an example:   
 

Rx AGC Mask:
Alarm Fault Mask

 
Use the W X arrow keys to select AlarmFault, or  Mask, and then press ENTER to accept the 
selection and return to the previous menu. Note the following: 
 

Mask Type

Description

Alarm

Alarms can be viewed from the Monitor: Live Alarms menu (Sect. 5.2.4.1). Alarms cause the Unit

Status LED to turn AMBER.

Fault

Faults can be viewed in the Monitor: Stored-Events log (Sect. 5.2.4.2). Faults cause:

• The Unit Status LED to turn RED
• The J1 Alarm Connector to show a Fault

Mask

Masking the event has the effect of ignoring the event – it can no longer be logged and is not seen in

any menu.

 
For the Reference and DeCompInv masking option selections, Alarm, Fault, and Mask (as 
previously described), plus an addition masking option, are available: 
 

Mask Type

Description

Fault-Tx On Faults can be viewed in the Monitor: Stored-Events log (Sect. 5.2.4.2). Faults cause:

• The Unit Status LED to turn RED
• The J1 Alarm Connector to show a Fault

 