Comtech EF Data CDM-750 User Manual

Page 202

Advertising
background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Serial-based Remote Product Management

MN-CDM750

7–22

Parameter

Type

Command

(Instruction

& Qualifier)

Number of

Arguments

Description of Arguments

Response to

Command

Query

(Instruction &

Qualifier)

Response to Query

Management

Default
IP Gateway

IPG=

15 bytes

numerical

Command or Query.

Set or return the IP Gateway Address for the Ethernet management port in the form aaa.bbb.ccc.ddd where:
aaa = 000-223
bbb = 000-255

ccc = 000-255
ddd = 001-255


Example: IPG=010.006.030.001.24

IPG=

IPG?
IPG*
IPG#

IPG?

IPG=xxx.xxx.xxx.xxx

(see Description of
Arguments)

Management

MAC Address

N/A

12 bytes,

alpha-
numerical

Query only.

Return the unique MAC Address for the modem in the form aabbccddeeff.

Example: MAC=0006B00001C2

N/A

MAC?

MAC=aabbccddeeff

(see Description of
Arguments)

GE1 Link

Configuration

LC1=

1 byte, value

of 0 thru 6

Command or Query.

Set or return the GE1 Interface mode in the form x, where:
0 = Auto Negotiate (default)

1 = 1000Mbps Full Duplex
2 = 100Mbps Full Duplex

3 = 100Mbps Half Duplex
4 = 10Mbps Full Duplex

5 = 10Mbps Half Duplex
6 = Off

LC1=

LC1?
LC1*

LC1#

LC1?

LC1=x

(see Description of
Arguments)

GE2 Link
Configuration

LC2=

1 byte, value
of 0 thru 6

Command or Query.
Set or return the GE2 Interface mode in the form x, where:

0 = Auto Negotiate (default)
1 = 1000Mbps Full Duplex

2 = 100Mbps Full Duplex
3 = 100Mbps Half Duplex

4 = 10Mbps Full Duplex
5 = 10Mbps Half Duplex

6 = Off

LC2=
LC2?

LC2*
LC2#

LC2?

LC2=x
(see Description of

Arguments)

Gig Optical

Ethernet
Interface

LC3=

1 byte, value

of 0 or 1

Command or Query.

GigE Optical Ethernet Interface mode, where x may be:
0 = Off

1 = On

NOTE: Option must be purchased and SFP module installed!

LC3=

LC3?
LC3*

LC3#

LC3?

LC3=x

(see descriptor
arguments)

Inband
Communi-

cations

SLC=

1 byte, value
of 0 or 1

Command or Query.
Set or return isolation (opening) or connection of the SERDES link between the management Ethernet port and

the data Ethernet ports, in the form x, where:
0 = Inband Disabled
1 = Inband Enabled

SLC=
SLC?

SLC*
SLC#

SLC?

SLC=x
(see Description of

Arguments)

Advertising