Comtech EF Data CDM-750 User Manual

Page 277

Advertising
background image

CDM-750 Advanced High-Speed Trunking Modem

Revision 2

Appendix D

MN-CDM750

D–19

D.5.2.2 Calculating CnC Ratio from Carrier to Noise Ratio (C/N) on a

Spectrum Analyzer

For this example, assume Site A is running a link 
to  Site  B  (referred  to  as  Link  1),  and  Site  B  is 
running a link to Site A (referred to as Link 2): 
 
 
 
 

CnC Ratio = C/N Interferer – C/N Desired + 10log(SR Interferer /

SR_Desired)

CnC Ratio at Site A = C/N Link 1 – C/N Link 2 + 10log(SR Link 1 /

SR Link 2)

CnC Ratio at Site B = C/N Link 2 – C/N Link 1 + 10log(SR Link 2 /

SR Link 1)

CnC Ratio from C/N

C/N (dB)

Symbol Rate (Msps)

CnC Ratio (by Carrier Direction)*

Link 1

Link 2

SR

Link 1

SR

Link 2

CnC A

(Site A Æ Site B)

CnC B

(Site B Æ Site A)

9.5

7.5

5.0

6.5

+0.86 dB

-0.86 dB

 
* Notes:  
 

• From the standpoint of Site A

 

CnC Ratio = 9.5 – 7.5 + 10log(5.0 / 6.5) = +0.86

 

• From the standpoint of Site B


CnC Ratio = 7.5 – 9.5 + 10log(6.5 / 5.0) = -0.86

 
 
 
 
  

Advertising