Spinner rpm, For example – Smithco Envizio Pro Installation & Operation Manual User Manual

Page 195

Advertising
background image

Manual No. 016-0171-148

185

Calculating the Calibration Values

Spinner RPM

For spinner box machines, use a product control node capable of controlling spinner speed.

Valve Type

Select the valve type currently used on the machine in which the field computer is installed.

Application

Select ‘Spinner’ as the application type. If spinner does not show up on the application rate, check that a CAN
control node capable of controlling spinner applications is connected to the CANbus. Check the CAN control
node and install a node that is capable of spinner control.

Meter Cal

The machine should be configured with a magnetic pickup coil mounted near the bolt heads on the spinner.
Calculate the meter cal by multiplying the number of pulses (bolt heads) per revolution by 10.

For Example:

If the number of pulses per revolution is 4:

then the value for the meter cal would be 40.

Spreader Constant

The spreader constant should be set to 0.

Rate Cal

The rate cal should be set to the desired RPM of the spinner.

MeterCal

N

10

×

=

4

10

×

40

=

Advertising
This manual is related to the following products: