558

11 Programming: Q-Parameters

1

1

.1

0 Pr

eassigned Q P

a

ra

met

e

rs

11.10 Preassigned Q Parameters

The Q parameters Q100 to Q122 are assigned values by the TNC. The
Q parameters are assigned:

„

Values from the PLC

„

Tool and spindle data

„

Data on operating status

„

Results of measurements from touch probe cycles etc.

Values from the PLC: Q100 to Q107

The TNC uses the parameters Q100 to Q107 to transfer values from
the PLC to an NC program.

WMAT block: QS100

The TNC saves the material defined in the WMAT block in parameter
QS100.

Active tool radius: Q108

The active value of the tool radius is assigned to Q108. Q108 is
calculated from:

„

Tool radius R (tool table or G99 block)

„

Delta value DR from the tool table

„

Delta value DR from the TOOL CALL block

Preassigned Q parameters between Q100 and Q199 must
not be used as calculation parameters in NC programs.
Otherwise you might receive undesired results.