Chapter 6 Specifications

RIGOL

DSG3000 User’s Guide

6-7

Phase Modulation

Operating modes

Internal, external, internal + external

Maximum deviation

f ≤ 23.4375MHz

3rad(nom.)

f > 23.4375MHz

N×5rad (nom.)

Resolution

<0.1% of deviation, or 0.01rad, whichever is greater, (nom.)

Deviation accuracy

f

mod

=1kHz, internal modulation

source

<1% of setting+0.1rad

ØM total harmonic

distortion

f

mod

=1kHz, deviation=5rad

<1% (typ.)

Modulation frequency

response

[1]

10Hz to 100kHz

<3dB (nom.)

Pulse Modulation

Modulation source

External, internal

On/off ratio

25MHz ≤ f < 3GHz

>80dB

3GHz ≤ f ≤ 6GHz

>70dB

Rise/fall time

(10%/90%)

<50ns

[1]

, 10ns (typ.)

Pulse repetition

frequency

DC to 1MHz

Pulse Generator

Operating modes

Single pulse, double pulse, pulse train(option PUG-DSG3000)

Pulse period

Setting range

40ns to 170s

Resolution

10ns

Pulse width

Setting range

10ns to (170s-10ns)

Resolution

10ns

Trigger delay

Setting range

10ns to 170s

Resolution

10ns

Double-pulse spacing Setting range

20ns to (170s-20ns)

Resolution

10ns

Triggering

Auto, external trigger, external gate, trigger key, bus (GPIB,

USB, LAN)

Pulse Train Generator (Option PUG-DSG3000)

Pulse train generator

Number of pulse patterns

1 ~ 2047

On/off time range

20ns to 170s

Repetition per pattern

1 to 256

NOTE: [1] External operating mode, measured at 5rad deviation.

[2]The state of ALC is off.