Sundance Spas ST201 User Manual

Page 54

Advertising
background image

54

Sundance Technology

ST201

PRELIMINARY draft 2

RECEIVEMODE

Class....................I/O Registers, Control and Status

Base Address ......IoBaseAddress register value

Address Offset .....0x5c

Access Mode .......Read/Write

Width ...................8 bits

Each bit in ReceiveMode, when set, enables reception of a different type of frame. ReceiveMode is cleared
upon reset.

BIT

BIT NAME

BIT DESCRIPTION

0

ReceiveUnicast

Setting this bit enables the ST201 to receive unicast frames that match
the 48-bit StationAddress of the ST201.

1

ReceiveMulticast

Setting this bit causes the ST201 to receive all multicast frames,
including broadcast.

2

ReceiveBroadcast

Setting this bit causes the ST201 to receive all broadcast frames.

3

ReceiveAllFrames

Setting this bit causes the ST201 to receive all frames promiscuously.

4

ReceiveMulticast-
Hash

Setting this bit enables the ST201 to receive frames that pass the hash
filtering mechanism.

5

ReceiveIPMulticast

Setting this bit enables the ST201 to receive all multicast IP data-
grams, which are mapped into Ethernet multicast frames with destina-
tion address of 01:00:5e:xx:xx:xx as defined in RFC 1112 and RFC
1700. The first 3 bytes require exact match, and the last 3 bytes are
ignored.

7..6

Reserved

Reserved for future use. Should be set to 0.