Sundance Spas ST201 User Manual

Page 89

Advertising
background image

89

Sundance Technology

ST201

PRELIMINARY draft 2

CARRIERSENSEERRORS

Class....................I/O Registers, Statistics

Base Address ......IoBaseAddress register value

Address Offset .....0x74

Access Mode .......Read (also clears register)/Write

Width ...................8 bits

BIT

BIT NAME

BIT DESCRIPTION

3..0

CarrierSenseErrors

This statistic register counts the number of times that carrier_sense
was not asserted or was de-asserted during the transmission of a
frame without collision. Carrier sense is not monitored for the purpose
of this statistic until after the preamble and start-of-frame delimiter.
This is a 4-bit counter that will stick at 0fh. An UpdateStats interrupt will
occur, if enabled, after the counter has counted through 0ch.

7..4

Reserved

Reserved for future use. Should be set to 0.