Polycom KIRK KWS6000 User Manual

Page 35

Advertising
background image

Deploying KIRK Wireless Server 6000

3–7

In the example below, base station No. 10 is down. As a consequence, base

station No. 11 must use the alternative sync way on No. 21.

Figure 3-4

Synchronization Chain with Alternative Sync Ways

Figure 3-5

Synchronization Chain with Alternative Sync Ways

• No. 0 is the Sync Master (can be numbered 0-255).
• No. 10 and No. 20: Primary and alternative sync on No. 0.
• No. 11: Primary sync on No. 10 and alternative sync on No. 21.
• No. 21: Primary sync on No. 20 and alternative sync on No. 11.

• No. 0 is the Sync Master (can be numbered 0-255).
• No. 10, No. 20, No. 30, and No. 40: Primary and alternative sync on No. 0.
• No. 11: Primary sync on No. 10 and alternative sync on No. 21.
• No. 21: Primary sync on No. 20 and alternative sync on No. 11.
• No. 31: Primary sync on No. 30 and alternative sync on No. 41.
• No. 41: Primary sync on No. 40 and alternative sync on No. 31.

Advertising