Procedure A: EMC Legato NetWorker

Quantum TC2201 User’s Guide

129

Procedure A: EMC Legato NetWorker

1

1

Start the Windows Registry Editor program (as shown in

figure 48

) as

follows:

a

a. Select Start>Run.

b

b. Enter the following value in the Open text box: regedt32

c

c. Press [Enter].

%SystemRoot%\Winnt\System32\regedt32.exe

2

Select Window> HKEY_LOCAL_MACHINE> System>
CurrentControlSet> Services> QntmDLT

(or depending on

tape device being tested) to make that window active.

3

Select Edit>Add Key and enter Parameters for Key Name to create

a key named Parameters, if one does not exist.

4

To create a key named Device, open the Parameters key by selecting
Edit>Add Key

and enter Device for Key Name.

5

To create a DWORD named MaximumSGList, open the Device key

by selecting Edit>DWORD and entering MaximumSGList for

DWORD Name.

6

Open the MaximumSGList Value Name and replace the existing

Value Data in Decimal with a number at least as large as the block

size you need for the device.

To calculate the value, use the following equation:

(Block_Size / 4) + 1 = Value

64k 17 decimal 11 hex

96k 25 decimal 19 hex

128k 33 decimal 21 hex

256k 65 decimal 41 hex

512k 129 decimal 81 hex

Note:

You can also open this program at the following location:

Note:

Block Size Decimal Value Hex Value: