Chapter 5
_________________________________________________________________________________________

_____________________________________________________________________________

BE6021-11

1316A-2 Multi Gas Monitor

LumaSense Technologies A/S

Instruction Manual

Page 88 of 97

5.1

Maintenance Items

5.1.1 Changing Zero Channel inlet filter

It is recommended to change the zero gas inlet filter at least once a

year.

- Remove the top cover.

- Remove the DS0790 filter by detaching the luerlok fittings.

- Install a new DS0790 filter.

Figure 5.1. Picture showing the DS0790 zero inlet dust filter.

5.1.2 Changing the fuses

On delivery, two 20 mm T 1.6A (VF0007A) slow-blow fuses are

installed in the monitor – one in the live and one in the neutral mains

feed. When replacing fuses always ensure that the correct fuses are

used.

To check and change the fuses:

1. Remove the power cable from the mains socket.

2. Insert a suitable screwdriver into both of the fuse holders and

unscrew the fuse holders. See

figure 5.2

.