HP EVA P6000 Storage User Manual

Page 137

Advertising
background image

1.

Enable CHAP for the iSCSI or iSCSI/FCoE controller-discovered iSCSI Initiator entry. CHAP
can be enabled via CLI only.

To enable CHAP for the iSCSI or iSCSI/FCoE controller-discovered iSCSI Initiator entry using
the iSCSI or iSCSI/FCoE controller CLI:
a.

If the iSCSI Initiator is not listed under the set chap command:

HP Command View Option: add the initiator iqn name string via HP Command
View’s Add Host tab.

Go to HP Command View and select Hosts then select Tab Add Host and enter
the iqn name string.

CLI Option: Enter the initiator add command and add the iSCSI Initiator that is about
to do discovery.

b.

If the iSCSI Initiator is listed under set chap command, then enable CHAP secret. For
example: CHAPsecret01.

Select the index of the iSCSI Initiator.

To Enable CHAP, select 0, then enter the CHAP secret.

2.

Enable CHAP for the iSCSI or iSCSI/FCoE controller iSCSI presented target:

To enable CHAP for the iSCSI or iSCSI/FCoE controller Discovered iSCSI Initiator entry
using the iSCSI or iSCSI/FCoE controller CLI:

Enter the set CHAP command.

Select the Presented Target the initiator will log in to.

Enable CHAP and enter a CHAP secret. For example: hpstorageworks

Set up the iSCSI Initiator

137

Advertising