Fabric setup and zoning – HP EVA P6000 Storage User Manual

Page 65

Advertising
background image

hba1-SCSI-target-id-31-fibre-channel-port-name="50001fe10027093b";

NOTE:

Replace the WWPNs in the example with the WWPNs of your array ports.

6.

If the qla2300 driver is version 4.13.01 or earlier, for each LUN that users will access, add
an entry to the /kernel/drv/sd.conf file:

name="sd" class="scsi" target=20 lun=1;

name="sd" class="scsi" target=21 lun=1;

name="sd" class="scsi" target=30 lun=1;

name="sd" class="scsi" target=31 lun=1;

If LUNs are preconfigured in the/kernel/drv/sd.conf file, after changing the configuration
file, use the devfsadm command to perform LUN rediscovery.

7.

If the qla2300 driver is version 4.15 or later, verify that the following or a similar entry is
present in the /kernel/drv/sd.conf file:

name="sd" parent="qla2300" target=2048;

To perform LUN rediscovery after configuring the LUNs, use the following command:

/opt/QLogic_Corporation/drvutil/qla2300/qlreconfig –d qla2300 -s

8.

Reboot the server to implement the changes to the configuration files.

NOTE:

The qla2300 driver is not supported for Oracle StorEdge Traffic Manager/Oracle Storage

Multipathing. To configure a QLogic FCA using the Oracle SAN driver stack, see

“Configuring

FCAs with the Oracle SAN driver stack” (page 62)

.

Fabric setup and zoning

To set up the fabric and zoning:
1.

Verify that the Fibre Channel cable is connected and firmly inserted at the array ports, host
ports, and SAN switch.

2.

Through the Telnet connection to the switch or Switch utilities, verify that the WWN of the
EVA ports and FCAs are present and online.

3.

Create a zone consisting of the WWNs of the EVA ports and FCAs, and then add the zone
to the active switch configuration.

4.

Enable and then save the new active switch configuration.

NOTE:

There are variations in the steps required to configure the switch between different

vendors. For more information, see the HP SAN Design Reference Guide, available for downloading
on the HP website:

http://www.hp.com/go/sandesign

.

Oracle StorEdge Traffic Manager (MPxIO)/Oracle Storage Multipathing

Oracle StorEdge Traffic Manager (MPxIO)/Oracle Storage Multipathing can be used for FCAs
configured with the Oracle SAN driver and depending on the operating system version, architecture
(SPARC/x86), and patch level installed. For configuration details, see the HP StorageWorks MPxIO
application notes
, available on the HP support website:

http://www.hp.com/support/manuals

.

NOTE:

MPxIO is included in the SPARC and x86 Oracle SAN driver. A separate installation of

MPxIO is not required.

In the Search products box, enter MPxIO, and then click the search symbol. Select the
application notes from the search results.

Oracle Solaris

65

Advertising