Delfield Model#: T40CUW

Refrigerant

404A

Compressor and wiring

Compressor and Capacity

6 HP Compressor

24,950 BTUH 4.1gpm waterflow @ -32˚F, 90 amb, 102.2

Cond: 18,090 BTUH @-40˚F, 85˚F inlet water, 105˚F

Condensing

Condensing Unit Wiring

208/230V/60Hz/3Ph

Max Fuse Size: 60A

Max Circuit Ampacity:42.3A

Control System

High Pressure Switch

Set Point: 450 psig, 380 psig re-set

Low pressure switch

Set Point: 25psig, Range = 15in to 100psig

Oil Pressure Differential Switch

Sensotronic Oil Pressure Switch

Compressor Reliability

Crankcase Heater

65 watts

Flow Control

Condenser Capacity Control

Head Pressure Control Set at 84˚F, 185psig

Reciever Capcity

55.4lbs. @ 90% liquid refrigerant fill (37.5lbs. max

refrigerant charge)

Accumulator

500 Cubic Inch Capacity

Oil Separator

Yes

Oil Filter

Yes

Optional Outdoor Hood

Delfield Model Number: CUHOOD

Shipping Weight

Condensing Unit

600 Lbs.

Outdoor Hood

100 Lbs.

Water cooled condensing unit water usage @ 85˚F incoming

water, 105˚F (250psig) R404a condensing:
6HP Condensing Unit
Evaporating Temperature

Condenser Water Usage (GPM)

-40˚F

3.15

-30˚F

4.1

-20˚F

5.2

-10˚F

6.4

0˚F

7.8

Ambient Operating Limits: 50˚F to 110˚F

Note: The Delfield Blast Chiller/Shock Freezer is wired independently of the remote

condensing unit. No interconnecting wiring is required between the blast chiller

and the condensing unit. All condensing units have units have crankcase heaters.

Condensing unit control systems are provided wired from the factory. Field

Connection is made by connecting supply power to the compressor contactor.

Outdoor condensing unit applications require the use of an optional UL listed hood,

delfield P/N CUHOOD, for protection from the elements. Water cooled units are not

recommended for outdoor installation.

Interconnecting piping, curbs or other mounting methods and refrigerant are not

included. Installation must be made by a qualified refrigeration technician. Piping runs

of greater than 100 feet require consultaion with the factory.