Figure 3.43: Oscilloscope controls

Each oscilloscope can trigger and hold the wave form of the signal being monitored. There are seven available
trigger modes:

Table 3.2. Trigger modes

Trigger Mode

Behavior

Free

automatically retriggers on the internal clock

Normal

triggers the drawing trace once channel input match-
es your trigger settings

Hold

triggers a drawing trace and holds the signal until
rearmed

Hold and Retrigger

same as Hold, but the trigger is automatically
rearmed

Timed Hold

same as Hold, but the trigger is automatically
rearmed after the desired “retrigger time”

Polarity Check

same as Hold, but displays all the data prior to the
trigger point and triggers on either polarity and either
slope

Timed Polarity Check

rearms after the desired “retrigger time”

Clip Capture

same as Polarity Check but triggers when signal
reaches full scale

Timed Clip Capture

rearms after the desired “retrigger time”

The Trigger Level slider sets the trigger threshold level in percent of full scale. 0 represents -∞ dBFS. When the
slider is to the right of 0 the scope will trigger on the positive portion of a full scale signal; when it is to the
left it will trigger on the negative portion of a full scale signal.

The Retrig Time slider controls the amount of time that the system waits before retriggering when a "Timed"
mode is selected.