CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision

7

Appendix C

MN/CDMQX.IOM

C–12

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

RX Reed-
Solomon (n,
k) values

RRS=

1 byte, value
of 0 through 3

Command or Query.

RX Reed-Solomon (n, k) values in the form x, where:

0=Unframed closed network (220,200)
1=EFD closed network (225,205)
2=IESS-310 compatible operation (219,201)
3=EDMAC mode, closed (200,180) – EDMAC only

Notes:
1. Selection is valid only when RFT=2 or RFT=5.
2. For D&I++, selection 0,1, and 2 are supported.

RRS=
RRS?
RRS*
RRS#
RRS$
RRS^
RRS@

RRS?

RRS=x
(see Description of
Arguments)

RX Data Rate

RDR=

9 bytes

Command or Query.

Query ONLY if Interface Type is Quad Drop & Insert (ITF=D).

RX Data Rate in the form xxxxx.xxx where:

In kbps, between 32 kbps and 20 Mbps

Resolution = 1 bps (see Chapter 5. FRONT PANEL OPERATION
for valid rates).

Example: RDR=02047.999

RDR=
RDR?
RDR*
RDR#
RDR$
RDR^
RDR@

RDR?

RDR=xxxxx.xxxx
(see Description of
Arguments)

RX Buffer
Clock Source

BCS

1 byte, value of
0 through 4

Command or Query.

RX buffer clock source in the form x, where:

0=Internal
1=Rx Satellite
2=Tx Terrestrial (grouped as modem only)
3=Insert (D&I++ mode only)
4=External (QDI Interface only)

Notes:

1. Rx Satellite is also available in D&I++ mode.
2. Rx Satellite and Tx Terrestrial are also available for QDI interface

type.

BCS=
BCS?
BCS*
BCS#
BCS$
BCS^
BCS@

BCS? BCS=x

(see Description of
Arguments)

Eb/No Alarm
Point

EBA= 4

bytes

Command or Query.

Eb/No alarm point in dB in the form xx.x where:

Range is between 0.1 and 16 dB.

Resolution = 0.1 dB

Example: EBA=12.3

EBA=
EBA?
EBA*
EBA#
EBA$
EBA^
EBA@

EBA? EBA=xx.x

(see Description of
Arguments)