2 led indicators – Mocomtech CDM-QX User Manual

Page 68

Advertising
background image

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®

Revision 7

Front Panel Operation

MN/CDMQX.IOM

5–2

5.1.2

LED Indicators

IMPORTANT

In general, the Alarm relay state will reflect the state of the
Front Panel LEDs. For example, if the Unit Status LED is
red, the Unit Alarm relay will be active, etc. The one
exception is the Transmit Traffic relay. This will only be
activated if a Transmit Traffic Fault exists – it does not
reflect the state of the Tx carrier.

The function of the eight front panel LED indicators is as follows:

LED

Condition

Unit Status

Red

A Unit Fault exists (Example: PSU fault)

Green

No Unit Faults

Note: Unit fault does not include Tx or Rx fault.

Transmit
Traffic

Green

No Tx Traffic Faults

Off

A Tx Traffic fault exists or the Tx Carrier is in OFF state

Note:

This LED corresponds to the selected slot, example <TX>.

Receive
Traffic

Green

No Rx Traffic Faults (demod and Viterbi decoder are locked,
everything is OK)

Off

An Rx Traffic fault exists (the demod may still be OK – check the
fault status of the unit from the Monitor menu).

Note:

This LED corresponds to the selected slot, example <RX>.

Online

Green

The Unit is On Line, and carrying traffic

Off

The Unit is Off Line (standby) - forced by externally connected 1:1
or 1:N redundancy system

Note:

This LED corresponds to the selected slot, example <RX>.

Stored Event

Orange

There is a Stored Event in the log, which can be viewed from the
front panel, or retrieved via the remote control interface

Off

There are no Stored Events

Remote

Orange

The Unit is in Remote Mode - local monitoring is possible, but no
local control

Off

The Unit is in Local Mode - remote monitoring is possible, but no
remote control

Flashing

ODU FSK control has been enabled, and there is a
communications fault.

EDMAC Mode

Orange

Framing on, EDMAC on, and unit defined as Slave - local
monitoring is possible, but no local control

Off

Either the unit is in Transparent mode (no framing), or the framing
has been selected, but in AUPC-only mode, or EDMAC Master
configuration.

Test Mode

Orange

A Test Mode is selected (Example: IF Loopback), or BERT
Generator is turned on, or BERT Monitor is turned on, or Spectrum
Analyzer is turned on.

Off

There is no Test Mode currently selected, BERT Generator is off,
BERT Monitor is off, and spectrum Analyzer is off.

Advertising