Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Retrieve next
5 unread
stored Events

N/A

80 bytes

Query only.

Unit returns the oldest 5 Stored Events, which have not yet been
read over the remote control, in the form {CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}, where Sub-
body = ABCCddmmyyhhmmss, where:

A being the fault/clear indicator
F=Fault
C=Clear
I =Info

B being the fault type where:
1=Unit
2=RX Traffic on Slot#1
3=RX Traffic on Slot#2
4=RX Traffic on Slot#3
5=RX Traffic on Slot#4
6=TX Traffic on Slot#1
7=TX Traffic on Slot#2
8=TX Traffic on Slot#3
9=TX Traffic on Slot#4
A=ODU
B=Power ON/OFF, or log cleared

CC is Fault Code numbers, as in FLT? Or Infor Code, which is:
0=Power Off
1=Power On
2=Log Cleared
3=Global Config Change
4=Redundancy Config Change

If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros.

If there are no new events, the response is RNE*.

N/A RNE?

RNE=
{CR}ABCCddmmyyhhmms
s{CR}ABCCddmmyyhhmm
ss{CR}ABCCddmmyyhhm
mss{CR}ABCCddmmyyhh
mmss{CR}ABCCddmmyyh
hmmss

(see Description of
Arguments)

Retrieved
next 5 unread
Stored
Statistics
(Modem Only)

N/A

130 bytes

Query only.

Unit returns the oldest 5 Stored Statistics, which have not yet been
read over the remote control, in the form {CR}Sub-body{CR}Sub-
body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where Sub-
body=AA.ABB.BC.CD.Dddmmyyhhmmss, where:

AA.A Minimum Eb/No during sample period
BB.B=Average Eb/No during sample period
C.C=Max. TX Power Level Increase during sample period
D.D=Average TX Power Level during sample period
ddmmyyhhmmss=date/time stamp

If there are no new events, the unit replies with RNS* If there are
less than 5 statistics to be retrieved, the remaining positions are
padded with zeros.

N/A RNS?

RNS={CR}
AA.ABB.BC.CD.Dddmmyy
hhmmss{CR}
AA.ABB.BC.CD.Dddmmyy
hhmmss{CR}
AA.ABB.BC.CD.Dddmmyy
hhmmss{CR}
AA.ABB.BC.CD.Dddmmyy
hhmmss{CR}
AA.ABB.BC.CD.Dddmmyy
hhmmss

(see Description of
Arguments)