MN/CDMQX.IOM
C–14
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
RX Spectrum
Invert
RSI=
1 byte, value of
0, 1
Command or Query.
RX Spectrum Invert in the form x, where:
0=Normal
1=RX Spectrum Invert
Example: RSI=0 (Normal)
RSI=
RSI?
RSI*
RSI#
RSI$
RSI^
RSI@
RSI? RSI=x
(see Description of
Arguments)
RX Demod
Acquisition
Sweep Width
RSW= 3
bytes
Command or Query.
RX acquisition sweep range of demodulator,in the form xxx, where:
xxx = in kHz, ranging from 001 to 032 kHz .
Example: RSW=009 (9 kHz)
RSW=
RSW?
RSW*
RSW#
RSW$
RSW^
RSW@
RSW? RSW=xxx
(see Description of
Arguments)
RX roll-off
(alpha) factor
RXA= 1
byte
Command or Query.
Rx roll-off (alpha) factor in the form x, where:
0=20%
1=35% (default)
RXA=
RXA?
RXA*
RXA#
RXA$
RXA^
RXA@
RXA RXA=x
(see Description of