Plat-1006, Plat-1007, Plat-1008 – Brocade Fabric OS Message Reference (Supporting Fabric OS v7.3.0) User Manual
Page 733

Fabric OS Message Reference
711
53-1003140-01
PLAT-1006
5
PLAT-1006
Message
Unknown midplane revision.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the chassis has a midplane whose revision is unknown.
This message occurs only on the Brocade M6505.
Recommended
Action
Install newer firmware in the Chassis Management Controller (CMC).
PLAT-1007
Message
BladeSystem Chassis type is unknown, setting maximum internal port speed to 8Gbps.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Onboard Administrator (OA) could be running an old version of firmware.
If OA firmware is new enough to support Enclosure Information, then OA failed to send the Enclosure
Information soon enough to allow the internal ports to run at 16 GFC.
This message occurs only on the Brocade 6548.
Recommended
Action
No action is required.
PLAT-1008
Message
BladeSystem Enclosure Information arrived late from OA.
Message Type
LOG
Severity
WARNING
Probable Cause
Indicates that the Onboard Administrator (OA) failed to send the Enclosure Information soon enough to
allow the internal ports to run at 16 GFC.
This message occurs only on the Brocade 6548.
Recommended
Action
Execute the hareboot command, followed by the portdisable and portenable commands to allow
internal ports to run at 16 GFC.