ADC AVIDIA SWD4573I1 User Manual
Page 218

Configuring SPVCs
192
Avidia System Configuration and Management User Manual
Examples
::spvc=>show
::spvc=>show 3.2 100 100
A screen similar to the following displays:
Information Description
Admin
The SPVC administrative status. Options:
•
Up—activated
•
Down—deactivated
Oper
The SPVC operational status. Options:
•
In Progress—attempting to connect
•
Connected—operational
•
Retries Exhausted—not operational
Source Slot
The channel card slot and port (format slot.port).
Source VPI
The VPI of the VCC between the CPE and the line card.
Source VCI
The VCI of the VCC between the CPE and the line card.
Destination Addr
The ATM address of the destination ATM end system.
Source TxTraf Index
The traffic descriptor profile index assigned to the SPVC transmitted traffic.
Source RxDesc Index
The traffic descriptor profile index assigned to the SPVC received traffic.
Last Rel Cause
The reason the SPVC was last disabled. This displays as a numeric code. See
Last Release Cause Codes” on page 607
for code definitions.
Retry Fail
The number of times the system has attempted to restart non-operational SPVC but
failed.
::spvc=>
Source
Dest
Admin Oper
Slot
VPI
VCI
Addr
up
connected
3.2
100
100
56:26:34:34:75:85:11:08
Source
Source
Last
TxTraf
RxDesc
Rel
Retry
Index
Index
Cause
Fail
4
4
???
2