Chapter 12: Monitoring
Subscriber
Connections
Avidia System Configuration and Management User Manual
269
Examples
::cell=> line 18.1
::cell=> line
A screen similar to the following displays.
The following table describes the information displayed by a line command.
Information
Description
Port
The slot and port for which the statics are displayed.
SDSL_State
The current status of the SDSL cell loop. Options:
•
Up
—
The line is up.
•
Down
—
The line is down.
•
Hand
—
The line is trying to connect.
•
Test
—
The line is in test mode.
•
Fail
—
The line has failed.
SNR
The signal-to-noise ratio margin of the signal received in dB.
Atn
The measured difference between the total signal power transmitted by the
sending unit and the total signal power received by the receiving unit in dB.
::cell=>line 18.1
Port
SDSL_State
SNR
Atn
18.1
down(2)
0
0
:cell=>line
Port
SDSL_State
SNR
Atn
18.1
down(2)
0
0
18.2
down(2)
0
0
18.3
down(2)
0
0
18.4
down(2)
0
0