ADC AVIDIA SWD4573I1 User Manual
Page 505
 
Chapter 23: Configuring Frame Relay Interworking
Avidia System Configuration and Management User Manual
479
Status Box
Description
Admin Status
The administrative status of the frame channel card 
and line card connection: Up (activated) or Down 
(deactivated).
Channel Slot
The frame card slot number.
Channel Port
The frame card port number.
Line Slot
The line card slot number.
Line Port
The line card port number.
Line VPI
The fr VPI of the fr VCC between the frame channel 
card and the line card.
Line VCI
The fr VCI of the fr VCC between the frame channel 
card and the line card.
Data Link LMI Type
The Local Management Interface type, which defines a 
method of exchanging status information between the 
customer device and the network. The options are:
None—no LMI support
Rev-1—LMI Rev-1
Annex A—ITU 0.933 Annex-A
Annex D—ANSI T1 617 Annex-D
If the LMI type is set to None, the poll interval, inquiry 
interval, error threshold, and monitor events 
parameters are not used.
Data Link Poll Interval
The poll interval value, which is the number of seconds 
between LMI status inquiry messages (range: 5-30). 
Data Link Inquiry Interval
The inquiry interval value, which is the number of poll 
intervals before a full status inquiry message is sent 
(range: 1-255).
Data Link Error Threshold
The error threshold value, which is the number of 
consecutive poll intervals in which the LMI status 
inquiry messages are not received that are required for 
the link to be declared down (range: 1-10).
Data Link Monitor Events
The monitor events value, which is the number of poll 
intervals in which the LMI status inquiry messages are 
not received that are required for the link to be 
declared down (range: 1-10).