In the
PVCC Configuration Table
window, click
.
The
PVCC Configuration Table
window displays. The
PVCC Configuration Table
index number
is automatically assigned, therefore no
Index
box displays.
2
In the
Admin Status
box, select the desired setting (
Up
or
Down)
.
Up
activates the PVCC.
Down
deactivates the PVCC.
3
In the
Channel Slot
box, select the slot number you want to use for this PVCC.
4
In the
Channel Port
box, select the port number you want to use for this PVCC.
5
In the
Channel VPI
box, type the subscriber-side VPI for this PVCC. (The VPI is always zero
for frame channel cards.)
See the table on
for a summary of the supported VPI ranges for each card.
6
In the
Channel VCI
box, type a subscriber-side VCI for this PVCC.
Be sure the VPI/VCI combination specified in this step and
this port. Open the
PVCC Configuration Table
window to view the configured VCIs. See the
table on
for a summary of the supported VCI ranges for each card.
7
In the
Channel Type
box, select the service type. TLS is the default service type for all
channel cards except IDSL.
For an IDSL channel card, select the service type that is the same as that of the IDSL
modem. Select one:
TLS
,
RAMP1483
, or
PPP
.